MODEL
F PRE-FORMED LOOP DETECTOR APPLICATION
Ocean State Signal Co. Model F Loop Detectors
are designed for saw-cut installation.
ADVANTAGES: Wires sealed in rubber asphalt filled polypropylene
conduit.
Completely
tested prior to shipment:
No splices.
Shipped ready to install.
Patented expansion / contraction joints.
Reduced maintenance cost.
SPECIFICATIONS
Loops shall be constructed from polypropylene conduit with
3/8" I.D. (9.5 mm) and 5/8" O.D (16 mm). Conduit
shall be filled with hot rubberized asphalt which allows the
loop to remain flexible once cooled, prevent incursion of
moisture and set the turns of wire firmly in place. Loops
shall have 5" (13cm) expansion / contraction joints at
the corners to allow for movement of the pavement and to prevent
breakage of the wire and / or conduit due to this movement.
Each expansion / contraction joint shall have a schedule 80
Quintex Tee-cover over the corners.
The encapsulated copper loop wire shall be 16 gauge TFFN or
THHN stranded single conductor wire with PVC insulation and
nylon exterior jacket. (other gauges employed where called
for). Loops shall have 4 turns. (additional or less
turns where called for) Loop shall have one continuous
wire through the loop head and lead-in to prevent loop malfunctions
due to splicing.
Lead-in wire shall be encased in a non-conductive 250 psi
(1500 Kpa) flex hose constructed with a seamless extruded
polyester fiber braid reinforcement and a non-conducive, seamless
extruded urethane non-perforated jacket. Fill lead-in hose
completely with hot rubberized asphalt. Twist wires in all
lead-ins a minimum of three turns per foot (30cm) for the
entire length of the lead-in.
Attach lead-ins to loop heads with a schedule 80 CPVC tee.
For
more information or to receive a quotation please call Marlin
Controls, Inc. at 508-278-0446 or 203-743-6231 in Connecticut.
|