4
CHANNEL ( RACK MOUNTED ) LOOP AMPLIFIER
Marlin Controls, Inc. offers our LM series
of Loop MonitorsTM from Eberle Design which takes vehicle
detection one step further. They not only indicate vehicle
presence with great accuracy and reliability, but also monitor
the condition of the loop for diagnostic purposes. The LM624
Series meets or exceeds all standards specified in NEMA publication
TS 2-1992 section 6.5 (Inductive Loop Detectors).
DIAGNOSTIC FEATURES
Color-Coded, Separate LEDs for Detect & Fault Indication Eliminates
the confusion encountered with other detectors that use only
one LED to display both faults and detection. The Yellow Fault
LED works independently from the Red Detect LED to display
the type of fault: Short, Open or 25% change of inductance.
Each type of fault is indicated by a unique sequence of flashes
allowing the user to diagnose loop failures at a glance. Loop
monitorTM status is also available at the edge connector via
separate TS-2 standard status outputs. Automatic Tuning Environmental
Tracking 15 Levels of Sensitivity Four Loop Frequencies and
Sequential Scanning No manual tuning is required. Together,
these features greatly reduce the incidence of crosstalk.
Ensures reliable operation by continuously adjusting for changes
in ambient conditions. Allows users to fine tune the Loop
MonitorTM to their application.
Three
Selectable Modes Pulse: For counting and volume. Short Presence:
For normal detection.
Long Presence:
For sites where loops may
be occupied for extended periods of time.
DETECTION FEATURES
Fault Memory Delay and Extension Timing on all FOUR channels.
Options Records previous fault information. If a problem self-
heals, the LM624 will resume normal operation. The contents
of the memory will be displayed on the Fault LED. This feature
can be used to isolate the source of intermittent loop failures.
For more information or to receive a quotation please call
Marlin Controls, Inc. at 508-278-0446 or 203-743-6231 in Connecticut.
|